Doors against vandalism

Elevator doors according to EN 81-71 – safety precautions against vandalism

As a part of the lift standard 81-71 introduced in 2005 to protect against vandalism, buildings and elevators will be based on their usage and the expected wanton destruction divided into three categories:


0 = rare and slight damage like it is possible in every building
      (office, hotel, mall)

1 = betimes and measured vandalism
      (hotels in critical districts, office with many visitors)

2 = heavy vandalism / robust accomplishment is claimed
      (every public building in critical districts, event halls)

As a long lasting experienced door expert, the ETG Elevator Trading GmbH reacted on these accomplishments and can provide the certified door type Marathon in all categories.

Categories 0 and 1

Landing door

  • adapted retaining device in case of breakdown of the upper guiding
  • reinforced sliding carriage, massive upper door panel fastening and reinforced lower door panel guide
  • changed door panel construction to abolish the impact energy
  • door panel size 1,5mm with additional stiffening
  • doors fulfil fire protection demand according to EN81-58

Cabin door

  • reinforced sliding carriage, massive upper door panel fastening and reinforced lower door panel guide
  • door panel size 1,5mm with additional stiffening
  • special door panel construction to abolish the impact energy

Elevator doors according to DIN EN 81-71 // 2 panel one side opening landing and cabin door

Landing and cabin door 2PSO EN81-71 Categorie 2

Categorie 2

Landing door

  • same basical construction as categories 0 and 1
  • covering of crossbar to protect the mechanic
  • electrical protection of the emergency device
  •  door panel size 2,0 mm with edging for grip
    protection
  • closing edge with labyrinth
  • door frames, door panels and sills in stainless steel 1.4301 (AISI 304)
  •  
  • doors fulfil fire protection demand according
    to EN 81-58

Cabin door

  • same basical construction as categories 0 and 1
  • covering of cross bar to protect the mechanic
  • door panel size 2,0 mm with edging for grip protection
  • closing edge with labyrinth
  • door panels and sills out of stainless steel 1.4301
  • frame at closing edge as a part of the cabin door
  • with cabin door interlock

Available door widths according to EN 81 – 71 in categories 0, 1 and 2 incl. EN81-58

type
Door width (mm)
2PSO 700 800 900 1000
3PSO 700 800 900 1000 1100 1200 1300 1400 1500
2PSO 700 800 900 1000
4PSO 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000
6PSO 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2600 2700 2800 2900 3000

door heights 2000mm und 2100mm (further door widths and heights on demand)

Paris