Elevator doors according to EN 81-71 - safety precautions against vandalism

As a part of the lift standard 81-71 introduced in 2005 to protect against vandalism, buildings and elevators will be based on their usage and the expected wanton destruction divided into three categories:


0 = rare and slight damage like it is possible in every building
      (office, hotel, mall)

1 = betimes and measured vandalism
      (hotels in critical districts, office with many visitors)

2 = heavy vandalism / robust accomplishment is claimed
      (every public building in critical districts, event halls)

As a long lasting experienced door expert, the ETG Elevator Trading GmbH reacted on these accomplishments and can provide the certified door type Marathon in all categories.tue eng vandalentuer01

Categories 0 and 1

Landing door

  • adapted retaining device in case of breakdown of the upper guiding
  • reinforced sliding carriage, massive upper door panel fastening and reinforced lower door panel guide
  • changed door panel construction to abolish the impact energy
  • door panel size 1,5mm with additional stiffening
  • doors fulfil fire protection demand according to EN81-58

Cabin door

  • reinforced sliding carriage, massive upper door panel fastening and reinforced lower door panel guide
  • door panel size 1,5mm with additional stiffening
  • special door panel construction to abolish the impact energy

 

 

 

Elevator doors according to DIN EN 81-71 // 2 panel one side opening landing and cabin door

Landing and cabin door 2PSO EN81-71 Categorie 2

tue eng vandalentuer02

 

Categorie 2

Landing door

  • same basical construction as categories 0 and 1
  • covering of crossbar to protect the mechanic
  • electrical protection of the emergency device
  •  door panel size 2,0 mm with edging for grip
    protection
  • closing edge with labyrinth
  • door frames, door panels and sills in stainless steel 1.4301 (AISI 304)
  • doors fulfil fire protection demand according
    to EN 81-58

Cabin door

  • same basical construction as categories 0 and 1
  • covering of cross bar to protect the mechanic
  • door panel size 2,0 mm with edging for grip protection
  • closing edge with labyrinth
  • door panels and sills out of stainless steel 1.4301
  • frame at closing edge as a part of the cabin door
  • with cabin door interlock

tue ger vandalentuer03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available door widths according to EN 81 - 71 in categories 0, 1 and 2 incl. EN81-58

tue eng vandalentuer04

 door heights 2000mm und 2100mm (further door widths and heights on demand)